This standard is issued under the fixed designation D ; the number 1 This practice is under the jurisdiction of ASTM Committee D on Protective. ASTM D Standard Practice for Surface Cleaning Concrete for Coating. ASTM D (Plastic sheet test): Place plastic sheet on concrete stab for 24 hours. o ASTM-D Standard Practice for Surface Cleaning Concrete for.

Author: Shazahn Brajas
Country: Mali
Language: English (Spanish)
Genre: Marketing
Published (Last): 13 January 2015
Pages: 121
PDF File Size: 4.32 Mb
ePub File Size: 14.36 Mb
ISBN: 445-2-76202-284-3
Downloads: 19011
Price: Free* [*Free Regsitration Required]
Uploader: Bragis

The steps below are provided for assistance in properly preparing various common substrates before coating.

If necessary, pressure clean with a minimum of psi to remove all dirt, dust, oil, grease, laitance, loose particles, foreign material, and peeling or defective coatings. Mill scale and rust cannot be removed by solvent cleaning.

Clean off the paste residue. This standard is not asstm in any packages. Small residues of rust and paint may be left in the lower portions of pits if the original surface is pitted.

Treat textured, soft, porous, or powdery plaster with a solution of 1 pint household vinegar to 1 gallon of water. Mill scale, paint, and rust that is tightly adhered to the surface may remain even after Brush-Off Blast Cleaning. Please first verify your email before subscribing to alerts.

Standards Subscriptions f4258 ANSI provides a money-saving, multi-user solution for accessing standards. Plan accordingly to handle the runoff. When viewed without magnification, a White Metal Blast Cleaned surface should be free of any visible grease, oil, dust, dirt, mill scale, paint, rust, oxides, corrosion products, and other foreign v4258. Clean steel using one or more of the nine surface preparations described below.

Repeat until the surface is hard. The subject of surface preparation leads me to recall my own home interior painting projects. We have no amendments or corrections for this standard. Ensure that knots and pitch streaks are scraped, sanded, and spot primed before a full priming coat is applied. When viewed without magnification, a Near-White Blast Cleaned surface should be free of any visible grease, oil, dust, dirt, mill scale, paint, rust, oxides, corrosion products, and other foreign matter, with the exception of staining.

TOP Related Posts  DE CHAPULTEPEC AL BEAGLE PDF

Aastm areas must be repaired with an f4258 patching material. Tape and cover joints with a joint compound. All loose rust, loose mill scale, loose and other detrimental foreign matter can be removed by power tool cleaning. Allow the coating to dry at least one week before testing for adhesion. Rinse carefully and allow to dry.

Remove all dust, oil, wax, grease, loose paint, mill scale, rust, dirt, mold, mildew, mortar, efflorensence, sealers, and other surface contaminants. If the surface is new, test it for pH, many times the pH may be 10 or higher.

Standard Practice for Surface Cleaning Concrete for Coating

This standard is also available to be included in Standards Subscriptions. High-pressure water blasting is commonly used to clean substrates. Ensure that all surface contamination has been removed by washing with an appropriate cleaner. Allow to dry and cure thoroughly for at least 30 days prior to painting.

Make sure all spackled nail heads and tape joints are sanded smooth and all dust removed prior to painting. Prime and paint as soon as possible after surface prep. Visible deposits of grease or oil must be removed prior to power tool surface preparation by any method specified xstm SSPC-SP 1, Solvent Cleaning, or other agreed upon methods.

Ensure that the surface is clean and free of any loose stucco, and that surface pH is between 6 and 9.

TOP Related Posts  FILE NLSSRV32 EXE IS NOT CURRENT VERSION NITRO PDF

ASTM D – 05() – Standard Practice for Surface Cleaning Concrete for Coating

Procedures include broom cleaning, vacuum cleaning, air blast cleaning, water cleaning, detergent water cleaning, and steam cleaning. Store finishing lumber and flooring in dry, warm rooms to prevent absorption of moisture, shrinkage, and roughening of the wood.

Your Alert Profile lists the documents that will be monitored. So many corrosion protection lining projects succeed or fail with the quality of the surface preparation achieved before the lining is even installed.

To test compatibility, apply a square foot area with the coating system, and allow concrete to dry one week before testing adhesion per ASTM D Rinse with clear water and allow to dry. This practice includes surface cleaning of concrete to remove grease, dirt, and loose material prior to the application of coatings.

When viewed without magnification, a metallic surface prepared according to this specification should be free of any visible grease, oil, dust, dirt, mill scale, paint, rust, oxides, corrosion products, and other foreign matter.

Method of cleaning steel to remove dirt, oil, grease, loose rust, loose mill scale, and loose paint using water at pressures of 2, to 2, psi at a flow of 4 to 14 gallons per minute.

Sand surfaces smooth, taking care to sand with the grain. When weathering is not possible or the surface has been treated with chromates or silicates, first Solvent Clean per SSPC-SP1 and apply a test area, priming as required.

Proceed to Checkout Continue Shopping. Established by the Steel Structures Council inthese methods are used throughout the world for describing methods for cleaning structural steel.